首页 > 其他分享 >S7-1511C-1 主要功能介绍

S7-1511C-1 主要功能介绍

时间:2023-12-12 10:46:38浏览次数:32  
标签:max S7 Number 介绍 range 1511C output Yes per

https://mall.industry.siemens.com/mall/en/WW/Catalog/Products/10268309?activeTab=productinformation&regionUrl=WW

 

CPU 1511C-1 PN
Ordering data Accessories Product Information Configurators
Jump to
Overview
Application
Design
Function
Technical specifications
More information
Overview
The compact CPU with integral digital and analog inputs and outputs in the product spectrum of the S7-1500 Controllers
With integrated technological functions, e.g. high-speed counter (HSC), frequency measurement, period duration measurement or stepper motor control, pulse width modulation, frequency output
Suitable for applications with medium requirements for program scope and processing speed
Used as central PLC in production lines with central and distributed I/O
PROFINET IO IRT interface with 2-port switch
PROFINET IO controller for operating distributed I/O on PROFINET
PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under a SIMATIC or non-Siemens PROFINET IO controller
OPC UA Server and Client as runtime option for the easy connection of SIMATIC S7-1500 to non-Siemens devices/systems with the functions:
OPC UA Data Access
OPC UA Security
OPC UA Methods Call
Support of OPC UA Companion specifications
OPC UA Alarms & Conditions
Isochronous mode (distributed)
Integrated Motion Control functionalities for controlling speed-controlled and positioning axes, support for external encoders, output cams/cam tracks and probes
Integrated web server for diagnostics with the option of creating user-defined web pages
Note

SIMATIC Memory Card required for operation of the CPU.


Application
The CPU 1511C-1 PN is the entry-level CPU for applications with medium requirements for processing speed and speed of response in discrete production technology.

The CPU 1511C-1 PN has 5 analog inputs via which analog process signals, such as pressure or temperature, can be acquired. Of these, four inputs can be used for current or voltage measurement and one input for resistance test.
The analog outputs integrated directly on the CPU convert a 16-bit digital value into a current or a voltage and output this to the process. They are suitable for controlling proportional valves, for example.
By means of the 16 integrated digital inputs, 24 V DC signals from plant that can be recorded directly on the controller.
The 16 integrated digital outputs switch 24 V DC voltages and thus transfer internal signals from the controller to the plant.
The integrated counters offer the possibility of recording signals as fast as 100 kHz and evaluating the counter status or the current speed directly in the controller without the need for additional modules. The speed can be output as a frequency or period, or as a user-normalized speed.
The Motion Control functions of the CPU can use the counters as an actual position value and the analog outputs as a speed setpoint output. The 4 to 100 kHz outputs can be used to:

Directly control stepper motors
Output frequencies
or, via the PWM function:

Directly control valves or
Digitally transmit analog signals
In addition, the CPU offers comprehensive control functionalities via easy-to-configure blocks as well as the ability to connect drives via standardized PLC-open blocks.

The CPU 1511C-1 PN can be used as a PROFINET IO controller or as distributed intelligence (PROFINET I-Device). The integrated PROFINET IO IRT interface is designed as a 2-port switch so that a linear topology can be set up in the system.


Design
The CPU 1511C-1 PN features:

A powerful processor:
The CPU achieves command execution times as low as 60 ns per binary instruction.
A large work memory:
175 KB for program, 1 MB for data
Integrated inputs/outputs;
16 digital inputs and 16 digital outputs as well as 5 analog inputs and 2 analog outputs for current/voltage signals and an additional input for measuring temperature on the CPU.
SIMATIC Memory Cards as load memory:
permit additional functions such as data log and archives
Flexible expansion capability:
single-tier configuration with max. 32 modules (CPU + 31 modules)
Screen with functions for:
Displaying overview information such as IP address of the integrated interface, station name, plant designation, location identifier, etc.
Display and acknowledgment of diagnostic and user messages
Display of module information
Display of a user-definable logo
Showing display settings
Setting IP addresses
Setting the date and time
Selecting the operating mode
Resetting the CPU to factory settings
Backup and restoring of the project
disabling/enabling the display
Enabling of protection levels
PROFINET IO IRT interface:
for connecting distributed I/O via PROFINET.

Function
Performance

Faster command processing, depending on the CPU type, language extensions and new data types.
Even shorter response times of the CPUs due to considerably faster backplane bus.
Powerful network connection:
each CPU is equipped with PROFINET IO IRT (2-port switch) as standard interface.
Integrated technology
Connection of analog and PROFIdrive-capable drives via standardized blocks (PLCopen).
Support of speed-controlled and positioning axes as well as external encoders, precise position gearing between axes, cams/cam tracks and probes.
Integrated I/O, e.g. for the direct operation of stepper motors and analog axes or for the direct recording of HTL encoders.
Design of the counter functions in the configuration and programming compatible with the TM Count 2x24V module.
Trace functions for all CPU tags, both for diagnostics in real time as well as for sporadic error detection; can also be called via the web server of the CPU.
Comprehensive control functionalities, e.g. easy to configure blocks for automatic optimization of the control parameters for maximum control performance.
Security Integrated
Password-based know-how protection against unauthorized read-out and modification of program blocks.
Copy protection for tying individual blocks to the serial number of the SIMATIC Memory Card: The block can only run if the configured memory card is inserted in the CPU.
4-level authorization concept:
Communication to the HMI devices can also be restricted.
Manipulation protection:
The controller recognizes changed or unauthorized transmissions of the engineering data.
Design and handling
Display of overview information:
E.g. Station name, plant identifier, location designation, etc., diagnostic information, module information, display settings.
Possible operations on the display:
Set addresses of the CPU or connected Ethernet communications processors, set date and time, select operating mode of CPU, reset CPU to factory settings, disable/enable display, activate protection levels, acknowledge messages, backup and restoring of the project.
Integrated system diagnostics
System diagnostics information is displayed consistently and in plain text in the display, TIA Portal, HMI devices and Web server, even for messages from the drives, and updated even if the CPU is in STOP mode.
Integrated into the firmware of the CPU, no special configuration is required
SIMATIC Memory Card (required for operation of the CPU)
Used as a plug-in load memory or for updating the firmware.
Also for storing additional documents or csv files (for recipes and archives)
Creation of data blocks for storage/reading of data via SFCs of the user program
Datalog (archives) and recipes
Storage of csv files for recipes and archives on the SIMATIC Memory Card;
easy access to plant-relevant operating data using Office tools or via a Web server
Easy access to machine configuration data by means of a Web browser or SD card reader (two-way data exchange from and to the controller)
Programming
Programming with STEP 7 Professional, V13 SP 1 UPD 4 or higher
Migration tool for upgrading from SIMATIC S7-300/S7-400 to S7-1500, converts the program code largely automatically. Non-convertible code is logged and can be manually adapted.
S7-1200 basic programs can be transferred to S7-1500 by copy-paste.

Technical specifications
Article number

6ES7511-1CK01-0AB0

CPU 1511C-1 PN, 175 KB Prog, 1 MB Data

General information

 

Product type designation

CPU 1511C-1 PN

HW functional status

FS03

Firmware version

V2.9

Product function

 

● I&M data

Yes; I&M0 to I&M3

● Isochronous mode

Yes; With minimum OB 6x cycle of 625 µs (distributed)

Engineering with

 

● STEP 7 TIA Portal configurable/integrated from version

V17 (FW V2.9) / V15 (FW V2.5) or higher; with older TIA Portal versions configurable as 6ES7511-1CK00-0AB0

Configuration control

 

via dataset

Yes

Display

 

Screen diagonal [cm]

3.45 cm

Control elements

 

Number of keys

8

Mode buttons

2

Supply voltage

 

Rated value (DC)

24 V

permissible range, lower limit (DC)

19.2 V; 20.4 V DC, for supplying the digital inputs/outputs

permissible range, upper limit (DC)

28.8 V

Reverse polarity protection

Yes

Mains buffering

 

● Mains/voltage failure stored energy time

5 ms; Refers to the power supply on the CPU section

● Repeat rate, min.

1/s

Input current

 

Current consumption (rated value)

0.8 A; Without load; 9.8 A: CPU + load

Current consumption, max.

1 A; Without load; 10 A: CPU + load

Inrush current, max.

1.9 A; Rated value

I²t

0.34 A²·s

Digital inputs

 

● from load voltage L+ (without load), max.

20 mA; per group

Digital outputs

 

● from load voltage L+, max.

30 mA; Per group, without load

output voltage / header

 

Rated value (DC)

24 V

Encoder supply

 

Number of outputs

1; One common 24 V encoder supply

24 V encoder supply

 

● 24 V

Yes; L+ (-0.8 V)

● Short-circuit protection

Yes

● Output current, max.

1 A

Power

 

Infeed power to the backplane bus

10 W

Power consumption from the backplane bus (balanced)

8.5 W

Power loss

 

Power loss, typ.

11.8 W

Memory

 

Number of slots for SIMATIC memory card

1

SIMATIC memory card required

Yes

Work memory

 

● integrated (for program)

175 kbyte

● integrated (for data)

1 Mbyte

Load memory

 

● Plug-in (SIMATIC Memory Card), max.

32 Gbyte

Backup

 

● maintenance-free

Yes

CPU processing times

 

for bit operations, typ.

60 ns

for word operations, typ.

72 ns

for fixed point arithmetic, typ.

96 ns

for floating point arithmetic, typ.

384 ns

CPU-blocks

 

Number of elements (total)

4 000; Blocks (OB, FB, FC, DB) and UDTs

DB

 

● Number range

1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999

● Size, max.

1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB

FB

 

● Number range

0 ... 65 535

● Size, max.

175 kbyte

FC

 

● Number range

0 ... 65 535

● Size, max.

175 kbyte

OB

 

● Size, max.

175 kbyte

● Number of free cycle OBs

100

● Number of time alarm OBs

20

● Number of delay alarm OBs

20

● Number of cyclic interrupt OBs

20; With minimum OB 3x cycle of 500 µs

● Number of process alarm OBs

50

● Number of DPV1 alarm OBs

3

● Number of isochronous mode OBs

1

● Number of technology synchronous alarm OBs

2

● Number of startup OBs

100

● Number of asynchronous error OBs

4

● Number of synchronous error OBs

2

● Number of diagnostic alarm OBs

1

Nesting depth

 

● per priority class

24

Counters, timers and their retentivity

 

S7 counter

 

● Number

2 048

Retentivity

 

— adjustable

Yes

IEC counter

 

● Number

Any (only limited by the main memory)

Retentivity

 

— adjustable

Yes

S7 times

 

● Number

2 048

Retentivity

 

— adjustable

Yes

IEC timer

 

● Number

Any (only limited by the main memory)

Retentivity

 

— adjustable

Yes

Data areas and their retentivity

 

Retentive data area (incl. timers, counters, flags), max.

128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB

Extended retentive data area (incl. timers, counters, flags), max.

1 Mbyte; When using PS 6 0W 24/48/60 V DC HF

Flag

 

● Size, max.

16 kbyte

● Number of clock memories

8; 8 clock memory bit, grouped into one clock memory byte

Data blocks

 

● Retentivity adjustable

Yes

● Retentivity preset

No

Local data

 

● per priority class, max.

64 kbyte; max. 16 KB per block

Address area

 

Number of IO modules

1 024; max. number of modules / submodules

I/O address area

 

● Inputs

32 kbyte; All inputs are in the process image

● Outputs

32 kbyte; All outputs are in the process image

per integrated IO subsystem

 

— Inputs (volume)

8 kbyte

— Outputs (volume)

8 kbyte

per CM/CP

 

— Inputs (volume)

8 kbyte

— Outputs (volume)

8 kbyte

Subprocess images

 

● Number of subprocess images, max.

32

Hardware configuration

 

Number of distributed IO systems

32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)

Number of DP masters

 

● Via CM

4; A maximum of 4 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total

Number of IO Controllers

 

● integrated

1

● Via CM

4; A maximum of 4 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total

Rack

 

● Modules per rack, max.

32; CPU + 31 modules

● Number of lines, max.

1

PtP CM

 

● Number of PtP CMs

the number of connectable PtP CMs is only limited by the number of available slots

Time of day

 

Clock

 

● Type

Hardware clock

● Backup time

6 wk; At 40 °C ambient temperature, typically

● Deviation per day, max.

10 s; Typ.: 2 s

Operating hours counter

 

● Number

16

Clock synchronization

 

● supported

Yes

● in AS, master

Yes

● in AS, slave

Yes

● on Ethernet via NTP

Yes

Digital inputs

 

integrated channels (DI)

16

Digital inputs, parameterizable

Yes

Source/sink input

P-reading

Input characteristic curve in accordance with IEC 61131, type 3

Yes

Digital input functions, parameterizable

 

● Gate start/stop

Yes

● Capture

Yes

● Synchronization

Yes

Input voltage

 

● Type of input voltage

DC

● Rated value (DC)

24 V

● for signal "0"

-3 to +5V

● for signal "1"

+11 to +30V

Input current

 

● for signal "1", typ.

2.5 mA

Input delay (for rated value of input voltage)

 

for standard inputs

 

— parameterizable

Yes; none / 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms

— at "0" to "1", min.

4 µs; for parameterization "none"

— at "0" to "1", max.

20 ms

— at "1" to "0", min.

4 µs; for parameterization "none"

— at "1" to "0", max.

20 ms

for interrupt inputs

 

— parameterizable

Yes; Same as for standard inputs

for technological functions

 

— parameterizable

Yes; Same as for standard inputs

Cable length

 

● shielded, max.

1 000 m; 600 m for technological functions; depending on input frequency, encoder and cable quality; max. 50 m at 100 kHz

● unshielded, max.

600 m; for technological functions: No

Digital outputs

 

Type of digital output

Transistor

integrated channels (DO)

16

Current-sourcing

Yes; Push-pull output

Short-circuit protection

Yes; electronic/thermal

● Response threshold, typ.

1.6 A with standard output, 0.5 A with high-speed output; see manual for details

Limitation of inductive shutdown voltage to

-0.8 V

Controlling a digital input

Yes

Accuracy of pulse duration

Up to ±100 ppm ±2 μs at high-speed output; see manual for details

minimum pulse duration

2 µs; With High Speed output

Digital output functions, parameterizable

 

● Switching tripped by comparison values

Yes; As output signal of a high-speed counter

● PWM output

Yes

— Number, max.

4

— Cycle duration, parameterizable

Yes

— ON period, min.

0 %

— ON period, max.

100 %

— Resolution of the duty cycle

0.0036 %; For S7 analog format, min. 40 ns

● Frequency output

Yes

Switching capacity of the outputs

 

● with resistive load, max.

0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed output; see manual for details

● on lamp load, max.

5 W; 1 W with high-speed output, i.e. when using a high-speed output; see manual for details

Load resistance range

 

● lower limit

48 Ω; 240 ohms with high-speed output, i.e. when using a high-speed output; see manual for details

● upper limit

12 kΩ

Output voltage

 

● Type of output voltage

DC

● for signal "0", max.

1 V; With high-speed output, i.e. when using a high-speed output; see manual for details

● for signal "1", min.

23.2 V; L+ (-0.8 V)

Output current

 

● for signal "1" rated value

0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed output, observe derating; see manual for details

● for signal "1" permissible range, min.

2 mA

● for signal "1" permissible range, max.

0.6 A; 0.12 A with high-speed output, i.e. when using a high-speed output, observe derating; see manual for details

● for signal "0" residual current, max.

0.5 mA

Output delay with resistive load

 

● "0" to "1", max.

200 µs

● "1" to "0", max.

500 µs; Load-dependent

for technological functions

 

— "0" to "1", max.

5 µs; Depending on the output used, see additional description in manual

— "1" to "0", max.

5 µs; Depending on the output used, see additional description in manual

Parallel switching of two outputs

 

● for logic links

Yes; for technological functions: No

● for uprating

No

● for redundant control of a load

Yes; for technological functions: No

Switching frequency

 

● with resistive load, max.

100 kHz; For high-speed output, 100 Hz for standard output

● with inductive load, max.

0.5 Hz; Acc. to IEC 60947-5-1, DC-13; observe derating curve

● on lamp load, max.

10 Hz

Total current of the outputs

 

● Current per channel, max.

0.5 A; see additional description in the manual

● Current per group, max.

8 A; see additional description in the manual

● Current per power supply, max.

4 A; 2 power supplies for each group, current per power supply max. 4 A, see additional description in manual

for technological functions

 

— Current per channel, max.

0.5 A; see additional description in the manual

Relay outputs

 

● Number of relay outputs

0

Cable length

 

● shielded, max.

1 000 m; 600 m for technological functions; depending on output frequency, load, and cable quality; max. 50 m at 100 kHz

● unshielded, max.

600 m; for technological functions: No

Analog inputs

 

Number of analog inputs

5; 4x for U/I, 1x for R/RTD

● For current measurement

4; max.

● For voltage measurement

4; max.

● For resistance/resistance thermometer measurement

1

permissible input voltage for voltage input (destruction limit), max.

28.8 V

permissible input current for current input (destruction limit), max.

40 mA

Cycle time (all channels), min.

1 ms; Dependent on the parameterized interference frequency suppression; for details, see conversion procedure in manual

Technical unit for temperature measurement adjustable

Yes; °C/°F/K

Input ranges (rated values), voltages

 

● 0 to +10 V

Yes; Physical measuring range: ± 10 V

— Input resistance (0 to 10 V)

100 kΩ

● 1 V to 5 V

Yes; Physical measuring range: ± 10 V

— Input resistance (1 V to 5 V)

100 kΩ

● -10 V to +10 V

Yes

— Input resistance (-10 V to +10 V)

100 kΩ

● -5 V to +5 V

Yes; Physical measuring range: ± 10 V

— Input resistance (-5 V to +5 V)

100 kΩ

Input ranges (rated values), currents

 

● 0 to 20 mA

Yes; Physical measuring range: ± 20 mA

— Input resistance (0 to 20 mA)

50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC

● -20 mA to +20 mA

Yes

— Input resistance (-20 mA to +20 mA)

50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC

● 4 mA to 20 mA

Yes; Physical measuring range: ± 20 mA

— Input resistance (4 mA to 20 mA)

50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC

Input ranges (rated values), resistance thermometer

 

● Ni 100

Yes; Standard/climate

— Input resistance (Ni 100)

10 MΩ

● Pt 100

Yes; Standard/climate

— Input resistance (Pt 100)

10 MΩ

Input ranges (rated values), resistors

 

● 0 to 150 ohms

Yes; Physical measuring range: 0 ... 600 ohms

— Input resistance (0 to 150 ohms)

10 MΩ

● 0 to 300 ohms

Yes; Physical measuring range: 0 ... 600 ohms

— Input resistance (0 to 300 ohms)

10 MΩ

● 0 to 600 ohms

Yes

— Input resistance (0 to 600 ohms)

10 MΩ

Cable length

 

● shielded, max.

800 m; for U/I, 200 m for R/RTD

Analog outputs

 

integrated channels (AO)

2

Voltage output, short-circuit protection

Yes

Cycle time (all channels), min.

1 ms; Dependent on the parameterized interference frequency suppression; for details, see conversion procedure in manual

Output ranges, voltage

 

● 0 to 10 V

Yes

● 1 V to 5 V

Yes

● -10 V to +10 V

Yes

Output ranges, current

 

● 0 to 20 mA

Yes

● -20 mA to +20 mA

Yes

● 4 mA to 20 mA

Yes

Load impedance (in rated range of output)

 

● with voltage outputs, min.

1 kΩ

● with voltage outputs, capacitive load, max.

100 nF

● with current outputs, max.

500 Ω

● with current outputs, inductive load, max.

1 mH

Cable length

 

● shielded, max.

200 m

Analog value generation for the inputs

 

Integration and conversion time/resolution per channel

 

● Resolution with overrange (bit including sign), max.

16 bit

● Integration time, parameterizable

Yes; 2.5 / 16.67 / 20 / 100 ms, acts on all channels

● Interference voltage suppression for interference frequency f1 in Hz

400 / 60 / 50 / 10

Smoothing of measured values

 

● parameterizable

Yes

● Step: None

Yes

● Step: low

Yes

● Step: Medium

Yes

● Step: High

Yes

Analog value generation for the outputs

 

Integration and conversion time/resolution per channel

 

● Resolution with overrange (bit including sign), max.

16 bit

Settling time

 

● for resistive load

1.5 ms

● for capacitive load

2.5 ms

● for inductive load

2.5 ms

Encoder

 

Connection of signal encoders

 

● for voltage measurement

Yes

● for current measurement as 4-wire transducer

Yes

● for resistance measurement with two-wire connection

Yes

● for resistance measurement with three-wire connection

Yes

● for resistance measurement with four-wire connection

Yes

Connectable encoders

 

● 2-wire sensor

Yes

— permissible quiescent current (2-wire sensor), max.

1.5 mA

Encoder signals, incremental encoder (asymmetrical)

 

● Input voltage

24 V

● Input frequency, max.

100 kHz

● Counting frequency, max.

400 kHz; with quadruple evaluation

● Signal filter, parameterizable

Yes

● Incremental encoder with A/B tracks, 90° phase offset

Yes

● Incremental encoder with A/B tracks, 90° phase offset and zero track

Yes

● pulse encoder

Yes

● pulse encoder with direction

Yes

● pulse encoder with one impulse signal per count direction

Yes

Errors/accuracies

 

Linearity error (relative to input range), (+/-)

0.1 %

Temperature error (relative to input range), (+/-)

0.005 %/K

Crosstalk between the inputs, max.

-60 dB

Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)

0.05 %

Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)

0.02 %

Linearity error (relative to output range), (+/-)

0.15 %

Temperature error (relative to output range), (+/-)

0.005 %/K

Crosstalk between the outputs, max.

-80 dB

Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)

0.05 %

Operational error limit in overall temperature range

 

● Voltage, relative to input range, (+/-)

0.3 %

● Current, relative to input range, (+/-)

0.3 %

● Resistance, relative to input range, (+/-)

0.3 %

● Resistance thermometer, relative to input range, (+/-)

Pt100 Standard: ±2 K, Pt100 Climate: ±1 K, Ni100 Standard: ±1.2 K, Ni100 Climate: ±1 K

● Voltage, relative to output range, (+/-)

0.3 %

● Current, relative to output range, (+/-)

0.3 %

Basic error limit (operational limit at 25 °C)

 

● Voltage, relative to input range, (+/-)

0.2 %

● Current, relative to input range, (+/-)

0.2 %

● Resistance, relative to input range, (+/-)

0.2 %

● Resistance thermometer, relative to input range, (+/-)

Pt100 Standard: ±1 K, Pt100 Climate: ±0.5 K, Ni100 Standard: ±0.6 K, Ni100 Climate: ±0.5 K

● Voltage, relative to output range, (+/-)

0.2 %

● Current, relative to output range, (+/-)

0.2 %

Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

 

● Series mode interference (peak value of interference < rated value of input range), min.

30 dB

● Common mode voltage, max.

10 V

● Common mode interference, min.

60 dB; at 400 Hz: 50 dB

Interfaces

 

Number of PROFINET interfaces

1

1. Interface

 

Interface types

 

● RJ 45 (Ethernet)

Yes; X1

● Number of ports

2

● integrated switch

Yes

Protocols

 

● IP protocol

Yes; IPv4

● PROFINET IO Controller

Yes

● PROFINET IO Device

Yes

● SIMATIC communication

Yes

● Open IE communication

Yes; Optionally also encrypted

● Web server

Yes

● Media redundancy

Yes

PROFINET IO Controller

 

Services

 

— PG/OP communication

Yes

— Isochronous mode

Yes

— Direct data exchange

Yes; Requirement: IRT and isochronous mode (MRPD optional)

— IRT

Yes

— PROFIenergy

Yes; per user program

— Prioritized startup

Yes; Max. 32 PROFINET devices

— Number of connectable IO Devices, max.

128; In total, up to 256 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET

— Of which IO devices with IRT, max.

64

— Number of connectable IO Devices for RT, max.

128

— of which in line, max.

128

— Number of IO Devices that can be simultaneously activated/deactivated, max.

8; in total across all interfaces

— Number of IO Devices per tool, max.

8

— Updating times

The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data

Update time for IRT

 

— for send cycle of 250 µs

250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive

— for send cycle of 500 µs

500 μs to 8 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive

— for send cycle of 1 ms

1 ms to 16 ms

— for send cycle of 2 ms

2 ms to 32 ms

— for send cycle of 4 ms

4 ms to 64 ms

— With IRT and parameterization of "odd" send cycles

Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)

Update time for RT

 

— for send cycle of 250 µs

250 µs to 128 ms

— for send cycle of 500 µs

500 µs to 256 ms

— for send cycle of 1 ms

1 ms to 512 ms

— for send cycle of 2 ms

2 ms to 512 ms

— for send cycle of 4 ms

4 ms to 512 ms

PROFINET IO Device

 

Services

 

— PG/OP communication

Yes

— Isochronous mode

No

— IRT

Yes

— PROFIenergy

Yes; per user program

— Shared device

Yes

— Number of IO Controllers with shared device, max.

4

— activation/deactivation of I-devices

Yes; per user program

— Asset management record

Yes; per user program

Interface types

 

RJ 45 (Ethernet)

 

● 100 Mbps

Yes

● Autonegotiation

Yes

● Autocrossing

Yes

● Industrial Ethernet status LED

Yes

Protocols

 

Number of connections

 

● Number of connections, max.

96; via integrated interfaces of the CPU and connected CPs / CMs

● Number of connections reserved for ES/HMI/web

10

● Number of connections via integrated interfaces

64

● Number of S7 routing paths

16

Redundancy mode

 

● H-Sync forwarding

Yes

Media redundancy

 

— Media redundancy

only via 1st interface (X1)

— MRP

Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client

— MRP interconnection, supported

Yes; as MRP ring node according to IEC 62439-2 Edition 3.0

— MRPD

Yes; Requirement: IRT

— Switchover time on line break, typ.

200 ms; For MRP, bumpless for MRPD

— Number of stations in the ring, max.

50

SIMATIC communication

 

● PG/OP communication

Yes; encryption with TLS V1.3 pre-selected

● S7 routing

Yes

● S7 communication, as server

Yes

● S7 communication, as client

Yes

● User data per job, max.

See online help (S7 communication, user data size)

Open IE communication

 

● TCP/IP

Yes

— Data length, max.

64 kbyte

— several passive connections per port, supported

Yes

● ISO-on-TCP (RFC1006)

Yes

— Data length, max.

64 kbyte

● UDP

Yes

— Data length, max.

2 kbyte; 1 472 bytes for UDP broadcast

— UDP multicast

Yes; Max. 5 multicast circuits

● DHCP

Yes

● DNS

Yes

● SNMP

Yes

● DCP

Yes

● LLDP

Yes

● Encryption

Yes; Optional

Web server

 

● HTTP

Yes; Standard and user pages

● HTTPS

Yes; Standard and user pages

OPC UA

 

● Runtime license required

Yes; "Small" license required

● OPC UA Client

Yes

— Application authentication

Yes

— Security policies

Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

— User authentication

"anonymous" or by user name & password

— Number of connections, max.

4

— Number of nodes of the client interfaces, recommended max.

1 000

— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.

300

— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.

20

— Number of elements for one call of OPC_UA_MethodGetHandleList, max.

100

— Number of simultaneous calls of the client instructions for session management, per connection, max.

1

— Number of simultaneous calls of the client instructions for data access, per connection, max.

5

— Number of registerable nodes, max.

5 000

— Number of registerable method calls of OPC_UA_MethodCall, max.

100

— Number of inputs/outputs when calling OPC_UA_MethodCall, max.

20

● OPC UA Server

Yes; Data access (read, write, subscribe), method call, custom address space

— Application authentication

Yes

— Security policies

Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

— User authentication

"anonymous" or by user name & password

— GDS support (certificate management)

Yes

— Number of sessions, max.

32

— Number of accessible variables, max.

50 000

— Number of registerable nodes, max.

10 000

— Number of subscriptions per session, max.

20

— Sampling interval, min.

100 ms

— Publishing interval, min.

500 ms

— Number of server methods, max.

20

— Number of inputs/outputs per server method, max.

20

— Number of monitored items, recommended max.

1 000; for 1 s sampling interval and 1 s send interval

— Number of server interfaces, max.

10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"

— Number of nodes for user-defined server interfaces, max.

1 000

● Alarms and Conditions

Yes

— Number of program alarms

100

— Number of alarms for system diagnostics

50

Further protocols

 

● MODBUS

Yes; MODBUS TCP

Isochronous mode

 

Equidistance

Yes

S7 message functions

 

Number of login stations for message functions, max.

32

Program alarms

Yes

Number of configurable program messages, max.

5 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH

Number of loadable program messages in RUN, max.

2 500

Number of simultaneously active program alarms

● Number of program alarms

600

● Number of alarms for system diagnostics

100

● Number of alarms for motion technology objects

80

Test commissioning functions

 

Joint commission (Team Engineering)

Yes; Parallel online access possible for up to 5 engineering systems

Status block

Yes; Up to 8 simultaneously (in total across all ES clients)

Single step

No

Number of breakpoints

8

Status/control

 

● Status/control variable

Yes

● Variables

Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

● Number of variables, max.

— of which status variables, max.

200; per job

— of which control variables, max.

200; per job

Forcing

 

● Forcing

Yes

● Forcing, variables

Peripheral inputs/outputs

● Number of variables, max.

200

Diagnostic buffer

 

● present

Yes

● Number of entries, max.

1 000

— of which powerfail-proof

500

Traces

 

● Number of configurable Traces

4; Up to 512 KB of data per trace are possible

Interrupts/diagnostics/status information

 

Alarms

 

● Diagnostic alarm

Yes

● Hardware interrupt

Yes

Diagnoses

 

● Monitoring the supply voltage

Yes

● Wire-break

Yes; for analog inputs/outputs, see description in manual

● Short-circuit

Yes; for analog outputs, see description in manual

● A/B transition error at incremental encoder

Yes

Diagnostics indication LED

 

● RUN/STOP LED

Yes

● ERROR LED

Yes

● MAINT LED

Yes

● STOP ACTIVE LED

Yes

● Monitoring of the supply voltage (PWR-LED)

Yes

● Channel status display

Yes

● for channel diagnostics

Yes; For analog inputs/outputs

● Connection display LINK TX/RX

Yes

Supported technology objects

 

Motion Control

Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool

● Number of available Motion Control resources for technology objects

800

● Required Motion Control resources

— per speed-controlled axis

40

— per positioning axis

80

— per synchronous axis

160

— per external encoder

80

— per output cam

20

— per cam track

160

— per probe

40

● Positioning axis

— Number of positioning axes at motion control cycle of 4 ms (typical value)

5

— Number of positioning axes at motion control cycle of 8 ms (typical value)

10

Controller

● PID_Compact

Yes; Universal PID controller with integrated optimization

● PID_3Step

Yes; PID controller with integrated optimization for valves

● PID-Temp

Yes; PID controller with integrated optimization for temperature

Counting and measuring

● High-speed counter

Yes

Integrated Functions

 

Counter

● Number of counters

6; Of which max. 4x A/B/N

● Counting frequency, max.

400 kHz; with quadruple evaluation

Counting functions

 

● Continuous counting

Yes

● Counter response parameterizable

Yes

● Hardware gate via digital input

Yes

● Software gate

Yes

● Event-controlled stop

Yes

● Synchronization via digital input

Yes

● Counting range, parameterizable

Yes

Comparator

 

— Number of comparators

2; per count channel; see manual for details

— Direction dependency

Yes

— Can be changed from user program

Yes

Position detection

 

● Incremental acquisition

Yes

● Suitable for S7-1500 Motion Control

Yes

Measuring functions

 

● Measuring time, parameterizable

Yes

● Dynamic measurement period adjustment

Yes

● Number of thresholds, parameterizable

2

Measuring range

 

— Frequency measurement, min.

0.04 Hz

— Frequency measurement, max.

400 kHz; with quadruple evaluation

— Cycle duration measurement, min.

2.5 µs

— Cycle duration measurement, max.

25 s

Accuracy

 

— Frequency measurement

100 ppm; depending on measuring interval and signal evaluation

— Cycle duration measurement

100 ppm; depending on measuring interval and signal evaluation

— Velocity measurement

100 ppm; depending on measuring interval and signal evaluation

Potential separation

 

Potential separation digital inputs

 

● between the channels

No

● between the channels, in groups of

16

Potential separation digital outputs

 

● between the channels

No

● between the channels, in groups of

16

Potential separation channels

 

● between the channels and backplane bus

Yes

● Between the channels and load voltage L+

No

Isolation

 

Isolation tested with

707 V DC (type test)

Ambient conditions

 

Ambient temperature during operation

 

● horizontal installation, min.

-25 °C; No condensation

● horizontal installation, max.

60 °C; note derating data for onboard I/O in the manual. Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off

● vertical installation, min.

-25 °C; No condensation

● vertical installation, max.

40 °C; note derating data for onboard I/O in the manual. Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off

Ambient temperature during storage/transportation

 

● min.

-40 °C

● max.

70 °C

Altitude during operation relating to sea level

 

● Installation altitude above sea level, max.

5 000 m; Restrictions for installation altitudes > 2 000 m, see manual

configuration / header

 

configuration / programming / header

 

Programming language

 

— LAD

Yes

— FBD

Yes

— STL

Yes

— SCL

Yes

— GRAPH

Yes

Know-how protection

 

● User program protection/password protection

Yes

● Copy protection

Yes

● Block protection

Yes

Access protection

 

● protection of confidential configuration data

Yes

● Password for display

Yes

● Protection level: Write protection

Yes

● Protection level: Read/write protection

Yes

● Protection level: Complete protection

Yes

programming / cycle time monitoring / header

 

● lower limit

adjustable minimum cycle time

● upper limit

adjustable maximum cycle time

Dimensions

 

Width

85 mm

Height

147 mm

Depth

129 mm

Weights

 

Weight, approx.

1 050 g

 

More information
More information and downloads
Manuals

The SIMATIC S7-1500 manuals can be downloaded free of charge from the Internet (SIMATIC Customer Support) under this link.

TIA Portal - An Overview of the Most Important Documents and Links - Controllers

You can find the overview under this link.

SIMATIC S7-1500 Display Simulator

You can use the S7-1500 Display Simulator to familiarize yourself with the different setting options and functions on the display under this link.

General information

is available under this link.

The TIA Selection Tool

is available under this link.

标签:max,S7,Number,介绍,range,1511C,output,Yes,per
From: https://www.cnblogs.com/blj28/p/17896246.html

相关文章

  • 在CentOS7等老系统上配置clangd进行C/C++开发
    应该有许多公司开发机器上还是用着比较老的环境,比如CentOS7之类的。这类系统上很可能他的glibc的版本不到2.18,clangd要求的最低glibc版本就是2.18,因此我们没办法直接在这类老系统上运行clangd。但是vscode上微软的那个c++插件一坨史,慢不说,补全也差劲。我的要求有几点:不能升级......
  • 介绍 Vue3 的常见目录结构
    当着手使用Vue3开发项目时,理解其目录结构至关重要。Vue3的文件组织和模块分隔方式直接关系到项目的可维护性和扩展性。本文将深入探讨Vue3的标准目录结构,并提供一些实用的指南和推荐做法。在Vue3项目中,通常会有以下一些常见的目录和文件:src目录:src 目录是Vue3项目的......
  • 介绍 Vue3 的常见目录结构
    当着手使用Vue3开发项目时,理解其目录结构至关重要。Vue3的文件组织和模块分隔方式直接关系到项目的可维护性和扩展性。本文将深入探讨Vue3的标准目录结构,并提供一些实用的指南和推荐做法。在Vue3项目中,通常会有以下一些常见的目录和文件:src目录:src 目录是Vue3项目的......
  • 介绍 Vue3 的常见目录结构
    当着手使用Vue3开发项目时,理解其目录结构至关重要。Vue3的文件组织和模块分隔方式直接关系到项目的可维护性和扩展性。本文将深入探讨Vue3的标准目录结构,并提供一些实用的指南和推荐做法。 在Vue3项目中,通常会有以下一些常见的目录和文件:src目录:src 目录是Vu......
  • 介绍 Vue3 的常见目录结构
    当着手使用Vue3开发项目时,理解其目录结构至关重要。Vue3的文件组织和模块分隔方式直接关系到项目的可维护性和扩展性。本文将深入探讨Vue3的标准目录结构,并提供一些实用的指南和推荐做法。 在Vue3项目中,通常会有以下一些常见的目录和文件:src目录:src 目录是Vu......
  • 超算集群安装OpenFOAM-LIGGGHTS-CFDEM(普通用户权限-以CSU HPC CentOS7.9为例)
    普通用户权限超算集群安装OpenFOAM-LIGGGHTS-CFDEM,由于缺少root权限,无法根据CFDEM官方instruction进行安装。本文以CSU超算平台为例,利用普通用户权限进行编译安装。文章修正了已有教程中部分问题,特别感谢希望先生与记得小蘋初见教程。1.安装必要依赖包此部分在记得小蘋初见中......
  • GPIO - 介绍 【ChatGPT】
    https://www.kernel.org/doc/html/v6.6/driver-api/gpio/intro.htmlGPIO接口简介什么是GPIO?GPIO(通用目的输入/输出)是一种灵活的软件控制的数字信号。它们由许多种类型的芯片提供,并且对于使用嵌入式和定制硬件的Linux开发人员来说非常熟悉。每个GPIO代表连接到特定引脚或Ball......
  • 【Lidar】Laspy库介绍+基础函数(读取、可视化、保存、旋转、筛选、创建点云数据)
    ​1Laspy库介绍        laspy是一个Python库,主要用于读取、修改和创建LAS点云文件。该库兼容Python2.6+和3.5+,并且可以处理LAS版本1.0-1.3的文件。        在laspy库中,可以使用命令行工具进行文件操作,如格式转换和验证,以及比较LAS文件。此外,laspy还支持分块......
  • centos7安装jdk8
    1.去oracle官网下载jdk1.8,需要注册,下载后缀为.tar.gz,比如jdk-8u381-linux-x64.tar.gz2.上传到服务器,解压建立文件夹,将java安装到指定目录mkdir-p/home/java8由于java的安装包解压后默认套了一层,解压后默认会有jdk1.8.0_381这一层文件夹,我不想要,所以解压的时候......
  • 万界星空科技五金家具企业MES案例介绍
    五金家具行业MES解决方案MES系统如何与家具企业生产相匹配?相较于其它大多数工业软件,MES系统无疑是受企业欢迎的软件之一。MES系统处于制造生产企业信息化的核心领域,有着承上启下的作用。那MES系统如何与家具企业生产相匹配?五金家具行业的工艺特点:1、五金产品为机械加工件,加工......